Engineering SpecDeep dive into our Gen5 NVMe ingest pods, Reed-Solomon (8+4) fault domains, and Baltic optical ring.
View Real-Time Telemetry →
Storage Systems Engineering

Bare-Metal Storage Pods & Erasure Topology

Every Nordic Data Sync region is built from standardized, non-oversubscribed storage pods designed to survive simultaneous multi-disk, multi-server, and full rack power-bus failures without interrupting S3 API writes.

Gen5 NVMe Storage Chassis
Standardized 2U NVMe/SAS storage node in ARN-1 (Kista, Stockholm) with dual 100GbE ConnectX-6 Lx uplinks.

Gen-4 Vault Pod Bill of Materials (Per Node)

We publish our exact hardware specification so infrastructure architects can audit failure domains and IOPS ceilings:

ComputeAMD EPYC 9354P (32C/64T, Zen 4, PCIe 5.0 x128)
Memory512 GB DDR5-4800 ECC Registered (12-channel)
Write Journal4 × 7.68 TB Micron 7450 MAX U.3 NVMe (3 DWPD, PLP)
Bulk Vault Array36 × 24 TB Enterprise Helium SAS-4 / SATA (XTS-AES-256)
Network FabricDual NVIDIA ConnectX-6 Lx 2×100GbE (LACP + BGP EVPN)
Time & CryptoStratum-1 GNSS PTP + FIPS 140-3 PCIe HSM Root Anchor
Reed-Solomon 8+4 Erasure Coding
Each 64 MB coalesced extent is encoded over GF(2^8) SIMD AVX-512 instructions into k=8 data blocks + m=4 parity blocks across 12 distinct servers.

Deterministic Fault Tolerance

With RS(8, 4) placement rules, no two shards of the same object ever reside on the same physical chassis or top-of-rack switch. Any 8 of the 12 shards reconstruct the payload at wire speed.

Zero Write-Hole Journaling

Small PostgreSQL 16 MB WAL segments and Restic index packs commit immediately to 3-way NVMe raft journals (`< 1.8 ms` fsync), then coalesce asynchronously into immutable erasure stripes.

Autonomous Self-Healing

When SMART telemetry or read-latency outliers flag an aging drive, the cluster reconstructs missing shards onto hot spares across the 100GbE backend network at up to 18 GB/s.

Optical WAN & Transport Protocol Stack

Engineered for Cross-Border High-BDP Paths

Standard cloud storage endpoints rely on legacy CUBIC TCP stacks that collapse when WAN packet loss reaches even 0.2%. Our edge ingress stack is purpose-tuned for long-haul replication.

POP / Exchange IXP & Transit Carriers Port Speed Protocols
Stockholm (ARN-1) Netnod, Arelion (AS1299), GlobalConnect 2 × 100 GbE TLS 1.3, H2, QUIC H3
Helsinki (HEL-2) FICIX-2, Cinia C-Lion1, Elisa 2 × 100 GbE TLS 1.3, H2, QUIC H3
Frankfurt (FRA-1) DE-CIX Apollon, NTT, GTT, Cogent 4 × 100 GbE TLS 1.3, H2, QUIC H3
Moscow Edge (MOW-1) MSK-IX, Cloud Direct Peering 2 × 25 GbE TLS 1.3, H2, QUIC H3
European Optical Topology